Additional safety instructions for DC power supplies
- An external DC power supply must meet the criteria for LPS and PS2 as set out in DIN EN IEC 62368-1.
- Cables or uninsulated parts in circuits carrying dangerous voltages or currents must not be touched, either directly or indirectly.
- There must be a reliable functional earth connection.
- In the application, a suitable, easily accessible isolating device (e.g. an overcurrent protection device) must be used if the product itself cannot be disconnected.
- A disconnecting device, where present in or as part of the product, must disconnect both poles simultaneously.
- Connecting the electrical circuits of different products must not give rise to any electrical hazards.
- The power cables must be sized in accordance with the maximum electrical specifications stated on the type plate. See also the following standards: DIN EN IEC 62368-1, VDE0100, EN 60204-1 or EN 61010-1.