Power supply requirements
The external 24 V DC power supply must be equipped with protection and supply functions such as overcurrent protection, inrush current protection, overvoltage protection and undervoltage protection (brownout protection) in order to protect the product from fluctuations and interruptions in the power supply. Please note that the power supply must be capable of handling peak currents for several seconds.
NOTICE

Malfunctions caused by a power-on reset that is too short
- If a brownout occurs, the power supply unit must remain in the ‘off’ state for long enough to allow the internal voltages to discharge sufficiently. Failure to observe this ‘off’ state may result in parts of the product or peripheral devices no longer functioning properly, or may reduce the MTBF.
- The minimum ‘off’ state required to allow the internal voltages to discharge sufficiently depends on the power supply and other electrical factors. In order to determine the required ‘off state’, each case must be considered individually.
NOTICE

Connection not compliant with the manufacturer’s specifications.
- Ensure that the external 24 V DC power supply is used in accordance with the manufacturer’s instructions.
- Check that the minimum requirements for the immunity of the mains supply, as set out in EN 55024, are met.