Compact Control
C6 COMPACT II
The efficient design of the C6 COMPACT control system is truly impressive. It works without a superimposed operating system which means that it can dedicate all its computing power to soft PLC and motion task applications. In addition to the real-time EtherCAT master, a number of slave interfaces (CANOpen, PROFIBUS, PROFINET RT, Interbus, EtherCAT, POWERLINK slave) are optionally available, as well as a CAN master. With the options for variable communication connection to other fieldbuses, the compact PLC can take over the control of a complete system or can also be used as a subordinate controller. The real-time bus system provides coordination and synchronous running of the axes, and enables consistent communication and diagnostics across all levels up to the drive.
Highlights
- Impressive real-time performance thanks to a powerful 32-bit micro controller with an integrated floating-point unit
- Programming and code processing according to IEC 61131-3 via the COMBIVIS studio 6 development tool
- Rapid real-time bus system with integrated EtherCAT master
- Various slave interfaces available as optional equipment
- Four integrated digital inputs and outputs
Technical Data
C6 COMPACT II
CPU
| Processor / Mass memory | SH7269 - 32-Bit RISC Microcomputer SuperHTM RISC engine inc. Floating Point Unit |
|---|---|
| System memory | 256 MB Flash, Boot Application + files, 32 MB RAM, Code + Data |
| Retain memory | 32 KB |
Operating data
| Power supply | 18 … 30 V DC |
|---|---|
| Operating environment | -10 … 45 °C, Rel. humidity 5 . . . 80 % (without condensation) |
| Operating environment | -25 … 70 °C, Rel. humidity 5 . . . 80 % (without condensation) |
Approvals
| CE |
|---|
Interfaces
| Ethernet / EtherCAT | 1 x 100 Mbps (RJ45), 1 x 10/100 Mbps (RJ45) |
|---|---|
| HSP5 | 4 x KEB HSP5 (RJ45) |
| Serial | 1 x RS232/422/485 (DB15M) / MPI 187,5 kbit/s |
Options
| Fieldbus systems | Profibus Slave Interface, PROFINET Slave Interface, EtherCAT Slave Interface, CAN Master/Slave Interface, Interbus Slave Interface, POWERLINK Slave Interface |
|---|
DIGITAL I/O'S
| 4 x Digital input (1 x fast input: 100 µs) | |
| 4 x Digital output (24 V; max. 0.7 A per channel), short-circuit resistant |
In use in these areas of application
Wind energy
Certified pitch and yaw solutions ensure that the wind always comes from the right direction. To date, KEB has equipped over 40,000 wind turbines around the world with its solutions.