Terminal block X6

Voltage supply occcurs via terminal block X6. Depending on the variant, a 4-, 8-, 12- or 16-pole pluggable terminal block is used.

Assignment of terminal block X6

X6

PIN

Designation

Notes

1

24V

DC 24 V supply voltage (internally connected to pin 2)

2

24V

DC 24 V supply voltage (internally connected to pin 1)

3

0V

Reference potential to 24 V (internally connected to pin 4)

4

0V

Reference potential zu 24 V (internally connected to pin 3)

5-8

-

CAN

9-12

-

RS485

13-16

-

RS232

The terminals for the voltage supply are always identical, independent of the above design.

Notes

The connection terminals X6.1/X6.2 and X6.3/X6.4 are connected internally to create a daisy chain if required.

The 0 V terminals are not internally connected to earth.

The maximum permissible current via the terminal is 9.5 A and must not be exceeded.

The cables must be designed according to the current.